If you shut the air off, restart and get a rush of media this indicates the hose is blocking, make sure your blast hose is straight as possible when blasting, even my big blaster will cause problems if tight bends as abrasive builds up in bends, if you must bend make as gradual as possible, for a small blast pot i would not use river sand, too course to flow,

What size air compressor have you, do you have a water trap fitted, remember to drain the compressor tank, I blast in hot climate 40c run an air drier and large water traps on drier and pot and still draw moisture, on a real shit day you can see a blue moisture stream coming from nozzle,

What brand pot do u have, will look it up
__________________
Dave

If it dosent work use a bigger hammer